Top 10 Freezer Evaporator Coil Freezing Up Reviews And Buying Guide

If you’ve ever had a freezer evaporator coil freeze up, you know how much of a hassle it can be to thaw it out. But what causes a freezer evaporator coil to freeze up in the first place? And how can you prevent it from happening again? In this blog post, we’ll explore these questions and more.

Best 10 Freezer Evaporator Coil Freezing Up

Bestseller No. 1
Face Roller by Revlon, Oily Skin Control for Face Makeup, Oil Absorbing, Volcanic Reusable Facial Skincare Tool for At-Home or On-the-Go Mini Massage
  • LIKE BLOTTING PAPERS, BUT BETTER: This face roller is made of real volcanic stone, which soaks up excess oil instantly. It’s our secret for fresh, shine-free skin any time. Use it on a clean or finished face—it won’t mess up your makeup
  • MASSAGES AND MATTIFIES FACE: Rolling the stone roller across your skin feels heavenly, like a mini facial massage. Ditch your jade roller and use our 2-in-1 Mattifying face roller for oily and acne prone skin
  • EASY TO USE: Gently roll the face roller ball over your T-zone or anywhere skin is shiny. That’s it
  • LESS WASTE THAN BLOTTING PAPER: Unlike blotting papers for oily skin that are used once and thrown out, this oil-absorbing roller is reusable. To clean, twist the roller’s ring to unlock, and pull out the stone. Wash with a gentle cleanser, rinse, and air-dry before locking it back in
  • LIVE BOLDLY WITH REVLON MAKEUP: Revlon has the quality beauty tools and high-pigment, the bold color makeup you need to be yourself. Our tools for the face, eyes, and nails are everyday essentials elevated through function, form, or and material (but still amazingly affordable)
Bestseller No. 2
Fieldpiece SM480V SMAN Digital Manifold Wireless Data Logging
  • Advanced digital refrigerant manifold & micron gauge for HVAC & Refrigeration diagnostics & service
  • Fieldpiece digital manifold gauges accurately measure low & high pressure, with superheat and subcooling
  • Advanced digital refrigerant manifold has protected thermocouple jacks for pipe and outdoor temps
  • Four valve manifold with vacuum gauge has the ability for Job Link Psychrometer probes to connect to SMAN
  • Equipped with a data log and temperature compensated system tightness test
Bestseller No. 4
Randell RFCOI107 Equivalent 15-3/8" Evaporator Coil Part
  • Genuine OEM replacement part
  • Efficiency and ease-of-use are designed into the core of Randell's commercial refrigeration products
  • Genuine OEM parts provide safety, reliability, and optimal performance
  • Approved by original equipment manufacturer (OEM)
  • Intended only for designed and specified use
Bestseller No. 5
12V Compact Refrigeration Cooling Systems Air Conditioning Systems with Miniature Rotary Compressor - for Electric Vehicle Chiller Water Dispenser Freezer Electronics Cooling Module DIY (12V,1.9cc)
  • Maximum cooling temperature the micro dc a/c achieves, 15-20 degree C lower than that of your ambient temperature.It depends on your ambient temperature and space volume and insulation standard.Around 35 cubic feet(1 cubic meters) space will this effectively cool. Compact refrigeration cooling system kit includes mini rotary compressor,driver board, condenser, evaporator, capillary,etc.ATTEN: 1,535BTU,pls read the specifications carefully before purchasing,thank you for your cooperation.
  • Rated Voltage: DC 12V; Max Current : 10A; Power:150W; Rated current:1~ 8A,Capacity: 450W (1,535Btu). Micro air conditioner module is a compact solution for small & confined space cooling which is powered by battery, grid, car power and solar power.
  • Ultra compact direct refrigeration unit with miniature dc rotary compressor to enable peak performance,low vibration with anti-vibration cushion.
  • Portable Refrigeration cooling system is also available as an outdoor or indoor unit because of its lightest weight and smallest size.
  • Micro dc aircon - super small volume: 13.3*8.2*5.7 inch,super light weight: 5.0kgs (11.02lbs).For small space cooling such as cabins, cuddy cabins,EV (eletric vehicle), helicopter, cab,compact off-road camper,carriage cooling for trucks and other specialized vehicles such as excavation vehicles and agricultural vehicles,etc.
Bestseller No. 6
Duke 216516 Evaporator Coil
  • Genuine OEM replacement part
  • Duke Manufacturing develops solutions for the commercial foodservice industry including product holding equipment, steam tables, ware washing and more
  • Use genuine OEM parts for safety reliability and performance
  • Model number: 216516
Bestseller No. 7
Nordyne, Inc (Medallion Prod) 921704 A-Coil 13 Seer 3 Ton Medallion
  • Easy Compressor and Control Access - Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit
  • Compressor - All models utilize quiet and efficient Copeland Scroll Compressors
  • Aluminum micro-channel coil
  • R-410A Refrigerant - Earth friendly non-ozone-depleting refrigerant
  • 5 Year Limited All Parts and 10 Year Compressor - Proven to be a major benefit to the consumer.
Bestseller No. 8
Bestseller No. 9
Pioneer Diamante Series Ductless Mini-Split Air Conditioner Inverter Heat Pump Full Set with 16 Ft. Kit
  • High Efficiency Diamante Ductless Mini Split Inverter Heat Pump System
  • Use for both cooling and heating: 9000 BTU/hour with 20 SEER and 10. 5 HSPF efficiency
  • Diamante series carries a full line of low-ambient wall-mounted mini splits with capacities ranging from 9,000 BTU/hour to 36,000 BTU/hour for various residential and light commercial applications
  • Complete system set including: indoor (fan coil) section, outdoor (condenser) section, wireless remote controller with remote holder, 16 ft. L line set with other installation accessories, free vibration absorber feet for the condensing unit
  • Voltage: 115V, 60Hz, 1Ph
Bestseller No. 10
Goodman 2.5-3 Ton Vertical Cased Coil CAPF3137B6
  • Suitable for use with R-410A and R-22 refrigerants
  • Rust-proof, thermoplastic drain pans feature a low water-retention design
  • Check flowrater expansion device for heat pump or cooling-only applications
  • Rifled copper tubing and louvered aluminum fin coils on CAPF, CAUF, and CSCF coils
  • CAPF3137B6

What is a freezer evaporator coil?

Freezer Evaporator Coil Freezing Up
The evaporator is housed inside the freezer and is responsible for cooling the air in the freezer. The evaporator coil is a series of tubes that the liquid refrigerant absorbs the heat from the air passing over it. The refrigerant evaporates to a gas as it absorbs the heat, lowering the temperature of the air.

How does a freezer evaporator coil work?

The evaporator coil is designed to remove heat from the inside a freezer. If the evaporator coil gets too cold, ice will form on the outside of the coil. The ice insulates the coil from the air in the freezer so it can’t get back to work removing heat. This is what causes a freeze up.

The cause of a freeze up can vary depending on where the coil is located inside the freezer. It could be caused by the following:

1. A clogged filter
2. A Freon leak
3. The coil is covered in dust, pet hair, or other debris
4. An issue with your defrost heater

If your evaporator coil is located inside the freezer compartment, try to locate it and look to see if there is any frost or ice on it. This is a telltale sign that there is a problem with the coil.

Why do freezer evaporator coils freeze up?

While the evaporator coils are designed to be cold, they wont freeze. This means theyre at the right temperature. However, if the coils get too cold, it can result in the coils freezing and forming a block of ice. This is a sign that there is an issue with the defrost functions in the unit.

There are a few different causes for the defrost functions failing in a refrigerator. Ranging from something as simple as a dirty coil to a more serious issue with the defrost system.

What to do when your freezer evaporator coil freezes up

When your freezer evaporator coil freezes up, the airflow is blocked, and the cooling process is interrupted. This can cause your items to start to melt and may even cause the entire freezer to stop working. Before you jump to conclusions about the health of your freezer, check to see if the evaporator coils are the source of the problem.

A frozen evaporator coil is usually caused by a lack of airflow from the freezer fan, or a build-up of frost inside the freezer.

Dirty or faulty components: The air filter is responsible for filtering the air that flows into the air evaporator. The air filter keeps dust and other particles from touching the evaporator coils and freezing them. Sometimes these filters become clogged, causing the evaporator to freeze up. This is usually due to a bad gasket, or a clogged air filter. You will need to replace the air filter to fix the problem. A faulty thermostat may also be to blame. If the thermostat stops working, it may cause the freezer to stop cooling.

Frost buildup: If frost begins building up inside your freezer, it may cause the evaporator coil to freeze. Usually, the frost buildup in the freezer is due to a broken or maladjusted door gasket. The gasket can stop sealing properly, allowing warm air to enter the freezer.

The first thing you want to do is open the freezer door and inspect the evaporator coil. If the coil is iced over, you can check for any signs of frost inside the freezer.

freezer evaporator coil freezing up Buying Guide

Some models have an access panel in the back of the freezer, behind which is the evaporator coil. Pull out the access panel—it might be on a hinge—and remove any screws or fasteners holding the panel in place. Then slide it out or lift it off to get at the evaporator coil. If you don’t have an access panel, remove the back wall of the freezer to reach the evaporator coil.

You can also access the evaporator coil through the front of the freezer. Remove the toe plate, which is the kick plate at the bottom of the front of the freezer. Then reach up and remove the drip tray to expose the evaporator coil at the bottom.

Clean the evaporator coil with a stiff brush and a coil cleaning solvent. Spray the solvent on the coils and wait several minutes to let it do its work. Then brush the coils clean. Clean the drip tray, too—it is typically made of plastic, so you can wash it with soap and water.

The next step is to clean the condenser. Use a brush or vacuum cleaner to remove dirt, dust, and debris that have accumulated on the condenser. Be sure to clean around the fins in the condenser, too. Clean the condenser several times a year to keep it running at peak efficiency.